EasyManuals Logo

Siemens SIMOTICS T-1FW6 Configuration Manual

Siemens SIMOTICS T-1FW6
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #312 background imageLoading...
Page #312 background image
Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
310 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Technical data
1FW6160
Symbol
Unit
-xxB10-1Jxx
-xxB10-2Jxx
-xxB10-5Gxx
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
3.62
3.64
3.67
Recommended minimum volume flow
H,MIN
l/min
6.37
6.37
6.37
Cooling medium temperature increase
ΔT
H
K
8.17
8.21
8.29
Pressure drop
Δp
H
bar
0.755
0.755
0.755
Data for precision motor cooler *)
Maximum dissipated thermal power
Q
P,MAX
kW
0.391
0.392
0.396
Recommended minimum volume flow
P,MIN
l/min
2.52
2.52
2.52
Cooling medium temperature increase
ΔT
P
K
2.23
2.24
2.26
Pressure drop
Δp
P
bar
0.755
0.755
0.755
*) Parallel connection of main and precision motor cooler