Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
361
Technical data
1FW6190
Symbol
Unit
-xxB10-8Fxx
-xxB10-2Pxx
Data for precision motor cooler *)
Maximum dissipated thermal power
Q
P,MAX
kW
0.498
0.487
Recommended minimum volume flow
P,MIN
l/min
2.33
2.33
Cooling medium temperature increase
ΔT
P
K
3.08
3.01
Pressure drop
Δp
P
bar
0.795
0.795
*) Parallel connection of main and precision motor cooler