Technical data and characteristics
6.2 Data sheets and diagrams
1FW6 Built-in torque motors
460 Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Technical data
1FW6290
Symbol
Unit
-xxB20-0Lxx
-xxB20-2Pxx
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
8.27
8.32
Recommended minimum volume flow
H,MIN
l/min
14.1
14.1
Cooling medium temperature increase
ΔT
H
K
8.41
8.46
Pressure drop
Δp
H
bar
2.22
2.22
Data for precision motor cooler *)
Maximum dissipated thermal power
Q
P,MAX
kW
0.892
0.897
Recommended minimum volume flow
P,MIN
l/min
5.86
5.86
Cooling medium temperature increase
ΔT
P
K
2.19
2.2
Pressure drop
Δp
P
bar
2.22
2.22
*) Parallel connection of main and precision motor cooler