Setting the date/time
In this menu, you can set the date and time.
6HWGDWHWLPH
7LPH66PPVV
6\QFKURQL]DWLRQ
'DWHWWPPMMMM
&DQFHO
ႱႧ
1RQH
VDYH
Ⴑ
&
Ⴇ
1. Select the desired setting using the <▼> function key.
2. Change the setting using the numeric keys. You can delete incorrect entries using the <◀
C> function key.
3. Select the "synchronization" row. Make the desired setting.
– "None"
The AOP time is managed internally and is displayed in the upper right of the operating
screen.
– "AOP➙DRIVE"
The AOP time is recorded in the drive each time the AOP is powered up, and daily at
2:00 AM. If a valid synchronization is detected, the time stamp for faults and alarms is
displayed on the AOP in real time.
– "DRIVE ➙AOP"
This operating state requires that the drive be connected to and synchronized by a
master clock. Every time the AOP is powered up, and daily at 2:00 AM, the time of the
drive is adopted as the time of the AOP. If a valid synchronization is detected, the time
stamp for faults and alarms is displayed on the AOP in real time.
4. Select "Save". Confirm the setting with <OK>.
Extended settings
In this menu, you can make the following extended settings:
● Load the AOP settings from the CU
● Automatically acknowledge topology
Operation
8.2 Operation via the AOP30 operator panel
SINAMICS GM150 6SL3815-2LN41-4AA2
Operating Instructions 04/2017 155