EasyManua.ls Logo

Siemens SINAMICS S120 - Page 1026

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic information about the drive system
13.12 System rules, sampling times and DRIVE-CLiQ wiring
Drive functions
1026 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
The recommended settings are marked with
XX
in the Table; all other possible settings are
marked with X.
Table 13- 14 Pulse frequencies and current controller sampling times for servo control
Pulse fre-
quency [kHz]
Current controller sampling time [µs]
250.0
187.5
150.0
125.0
100.0
93.75
75.0
62.5
50.0
37.5
31.25
16.0
X
-
-
X
-
-
-
X
-
-
XX
13.333
-
-
X
-
-
-
X
-
-
XX
-
12.0 X - - - - - - - - - -
10.666
-
X
-
-
-
X
-
-
-
-
X
10.0 - - - - X - - -
XX
- -
8.888
-
-
-
-
-
-
-
-
-
X
-
8.0
X
-
-
X
-
-
-
XX
-
-
X
6.666
-
-
X
-
-
-
XX
-
X
X
-
6.4
-
-
-
-
-
-
-
-
-
-
X
5.333
-
X
-
-
-
XX
-
X
-
X
-
5.0
-
-
-
-
XX
-
-
-
X
-
-
4.444
-
-
-
-
-
-
X
-
-
-
-
4.0
X
-
-
XX
-
-
-
X
-
-
-
3.555
-
-
-
-
-
X
-
-
-
-
-
3.333
-
-
XX
-
X
-
X
-
-
-
-
3.2
-
-
-
-
-
-
-
X
-
-
-
2.666
-
XX
-
X
-
-
-
-
-
-
-
2.5
-
-
-
-
X
-
-
-
-
-
-
2.222
-
-
X
-
-
-
-
-
-
-
-
2.133
-
-
-
-
-
X
-
-
-
-
-
2.0
XX
-
-
X
X
-
-
-
-
-
-
1.777 - X - - - - - - - - -
1.666
-
-
X
-
-
-
-
-
-
-
-
1.6
-
-
-
X
-
-
-
-
-
-
-
1.333
-
X
X
-
-
-
-
-
-
-
-
Note
Clock cycle mix
Detailed information about the clock cycle mix for servo control is provided in Sectio
n Cycle
mix for servo control and vector control
(Page 1031).