EasyManua.ls Logo

Siemens SINAMICS S120 - Acceptance Tests; General Information about Acceptance Tests

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety Integrated Basic Functions
10.11 Acceptance test and acceptance report
Drive functions
724 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
9
10
11
12
13
14
15
16
17
18
19
20
22
23
10.11.4
Acceptance tests
10.11.4.1
General information about acceptance tests
Note
Conditions for the acceptance test
As far as possible, the acceptance tests are to be carried out at the maximum possible
machine speed and acceleration rates to determine the maximum braking distances and
braking times that can be expected.
Note
Non-critical alarms
When evaluating the alarm buffer you can tolerate the following alarms:
A01697 SI Motion: Motion monitoring test required
A01796 SI Motion CU: Waiting for communication
These alarms occur after every system startup and can be evaluat
ed as non-critical. You do
not need to include these alarms in the acceptance report.