EasyManua.ls Logo

Siemens SINAMICS S120 - Lowpass 2 Nd Order (PT2 Filter); Bandstop with Infinite Notch Depth

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Servo control
4.6 Current setpoint filter
Drive functions
106 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
4.6.1
Lowpass 2nd order (PT2 filter)
Transfer function:
Denominator natural frequency f
N
Denominator damping D
N
Table 4- 3 Example of a PT2 filter
Filter parameters
Amplitude log frequency curve
Phase frequency curve
Characteristic frequency
f
N
500 Hz
Damping D
N
0.7 dB
4.6.2
Bandstop with infinite notch depth
Table 4- 4 Example of band-stop with infinite notch depth
Filter parameters
Amplitude log frequency curve
Phase frequency curve
Blocking frequency f
Sp
=
500 Hz
Bandwidth (-3 dB) f
BB
=
500 Hz
Notch depth K = - dB
Reduction Abs = 0 dB

Table of Contents