EasyManua.ls Logo

Siemens SINAMICS S120 - Topology Example: Drives in V;F Control (Vector Control)

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A.3 Supported sample topologies
Drive functions
1052 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
A.3.5
Topology example: Drives in V/f control (vector control)
The following diagram shows the maximum number of controllable vector V/f drives with
additional components. The sampling times of individual system components are:
Active Line Module: p0115[0] = 250 µs
Motor Modules: p0115[0] = 500 µs
Terminal Module/Terminal Board p4099 = 2 ms
Figure A-7 Topology example of a vector drive line-up in V/f control

Table of Contents