12.3 Control Units without infeed control
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
917
12.3
Control Units without infeed control
To ensure that the drive line-up functions satisfactorily, you must ensure, among other
things, that the drives only draw power from the DC link when the infeed is in operation. In a
DC link line-up that is controlled by precisely one Control Unit and which includes a drive
object X_INF
1)
, the BICO interconnection p0864 = p0863.0 is established automatically
during commissioning.
1)
X_INF stands for all drive objects "Infeed"; i.e.: A_INF, B_INF, S_INF
In the following cases, the BICO input p0864 must be supplied manually:
Smart Line Modules without DRIVE-CLiQ (5 kW and 10 kW)
DC link line-up with more than one Control Unit
Examples: interconnecting "Infeed ready"
Smart Line Modules without DRIVE-CLiQ (5 kW and 10 kW)
Figure 12-3 Example: interconnecting a Smart Line Module without DRIVE-CLiQ