Appendix
A.4 Parameterization using the BOP20
Drive functions
1056 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
A.4.2
Displays and using the BOP20
Features
Status indicator
Changing the active drive object
Displaying/changing parameters
Displaying/acknowledging faults and alarms
Controlling the drive using the BOP20
Status indicator
The operating display for each drive object can be set using p0005 and p0006. Using the
operating display, you can change into the parameter display or to another drive object. The
following functions are possible:
Changing the active drive object
Press key "FN" and "Arrow up" -> the drive object number at the top left flashes
Select the required drive object using the arrow keys
Acknowledge using the "P" key
Parameter display
Press the "P" key.
The required parameters can be selected using the arrow keys.
Press the "FN" key -> "r00000" is displayed
Press the "P" key -> changes back to the operating display