EasyManua.ls Logo

Siemens SINAMICS S120 - Updating Firmware;Configuration on the Memory Card

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic functions
7.25 Upgrade the firmware and project
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
411
7.25.2.2
Updating firmware/configuration on the memory card
You can load a firmware or a configuration to the memory card of the drive with the aid of the
Web server. If required, firmware and configuration can be loaded at the same time.
Requirements
Existing drive project
Web server has been started
Firmware or configuration is packed in a zip archive
PG/PC is connected to the Control Unit (target device)
STARTER: "Download to file system" has been carried out
Calling the Manage config display area
Click the “Manage config" entry in the navigation.
The “Manage config" area is then displayed on the right in the Internet browser.
Figure 7-24 Web server display area: Manage config; the status on the right is only displayed
following an action
You can send new data or restore the previous update via this display area.