EasyManua.ls Logo

Siemens SINAMICS S120 - Edge Evaluation of the Zero Mark

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic functions
7.20 Tolerant encoder monitoring
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
375
Effect
You can calculate the influence of the filter time on the maximum possible speed as follows:
n_max [rpm] = 60 / (p0408 · 2 · r0452)
Here, p0408 is the pulse number of the rotary encoder.
Example
Specifications:
p0408 = 2048
r0452 = 10.24 [μs]
n_max is then calculated as follows:
n_max = 60 / (2048 · 2 · 10.24 · 10
-6
) = 1430 [rpm]
As a consequence, with this filter time you can operate the motor up to a maximum of 1430
rpm.
7.20.5
Edge evaluation of the zero mark
This functionality is suitable for encoders, where the zero mark ≥ 1 pulse wide. In this
particular case, errors would otherwise occur as a result of the edge detection of the zero
mark.
For a positive direction of rotation, the positive edge of the zero mark is evaluated and for a
negative direction of rotation, the negative edge. As a consequence, for encoders where the
zero mark is wider than one pulse, it is possible to parameterize them with equidistant zero
marks (p0404.12 = 1), i.e. the zero mark checks (F3x100, F3x101
1)
) are activated.
Commissioning
1. Set parameter p0437.1 = 1 to activate the "edge evaluation of the zero mark" function.
The factory setting p0437.1 = 0 keeps the operation at the known zero mark detection.

Table of Contents

Other manuals for Siemens SINAMICS S120

Related product manuals