Basic functions
7.20 Tolerant encoder monitoring
Drive functions
384 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
7.20.14
Dependencies
Parameter
Functionality
These functions can be freely combined with one
another
These functions
build on one
another from left
to right, and can
be combined with
the adjacent ones
Indices
1
2
3
4
5
6
7
8
9
10
11
p0405.2
Track monitoring
x
p0430.20
Speed calculation mode
x
p0430.21
Zero mark tolerance
x
p0430.22 Rotor position adaptation x
p0437.1
Zero mark edge detection
x
p0437.2 Actual position value correction
XIST1
x x
p0437.4
Edge evaluation
x
p0437.5
Edge evaluation
x
p0437.6 Freezing the actual speed for dn/dt
errors
x
p0437.7 Uncorrected encoder pulses accu-
mulate
x x
p0437.26
Deselection, track monitoring
x
p0438
Square-wave encoder filter time
x
r0452 Square-wave encoder filter time
display
x
p0453 Pulse evaluation zero speed
measuring time
x
p4680 Zero mark monitoring tolerance
permissible
x x
p4681 Zero mark monitoring tolerance
window limit 1 positive
x
p4682 Zero mark monitoring tolerance
window limit 1 negative
x
p4683 Zero mark monitoring tolerance
window alarm threshold positive
x
p4684 Zero mark monitoring tolerance
window alarm threshold negative
x
p4685
Speed actual value averaging
x
p4686
Zero mark, minimum length
x
x
p4688 Zero mark monitoring, number of
differential pulses
x x
p4689
Square-wave encoder diagnostics
x
x