Basic information about the drive system   
13.12 System rules, sampling times and DRIVE-CLiQ wiring 
  Drive functions 
1032  Function Manual, 11/2017, 6SL3097-4AB00-0BP5 
Current controller sampling times for cycle mix 
Consequently the smallest common multiple of the current and speed controller sampling 
times of all axes operated on the isochronous PROFIBUS is used to set the base cycle for 
T
i
, T
o
 and T
dp
. For a cycle mix, a compromise must be sought between the base cycle to set 
T
i
, T
o
 and T
dp
, and the required pulse frequency.  
Table 13- 22  Examples of cycle mixes for servo control 
Cycle mix: Current controller sampling times 
[µs] 
Base cycle for T
i
, T
o 
[µs] 
Base cycle for T
dp
, 
T
mapc
[µs] 
187.50
 +125.00  375  750 
Base cycles for the isochronous PROFIBUS for a cycle mix with 125 μs 
 
Table 13- 23  Examples for cycle mixes for vector control 
Cycle mix: Current controller sam-
pling times [µs] 
Base cycle for T
i
, T
o 
[µs] 
Base cycle for T
mapc
 
[µs] 
137.50
 +250.00  2750  2750  11000 
Base cycles for the isochronous PROFIBUS for a cycle mix with 250 μs