Servo control
4.13 Motor data identification
Drive functions
156 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
For linear motors (p0300 = 4xx), p1959 is pre-set so that only the q inductance, the
commutation angle offset and the high inertia mass are measured (p1959.05 = 1 and
p1959.10 = 1), as generally the travel limits do not permit longer travel distances in one
direction.
Figure 4-17 Equivalent circuit diagram for induction motor and cable
Figure 4-18 Equivalent circuit diagram for synchronous motor and cable