Basic functions
7.1 Switching over units
Drive functions
314 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Parameterization with STARTER
The function for unit system switchover in STARTER can be found via the menu path "Drive
object" > "Configuration" > "Units".
The reference parameters can be found via the menu path "Drive object" > "Configuration" >
"Reference parameters".
Overview of the important parameters (see SINAMICS S120/S150 List Manual)
p0010
Infeed, commissioning parameter filter
p0100
IEC/NEMA motor standard
p0349
Unit system, motor equivalent circuit diagram data
p0505
Unit system selection
p0595
Techn
ological unit selection
p0596
Technological unit reference variable
p2000
Reference speed reference frequency
p2001
Reference voltage
p2002
Reference current
p2003
Reference torque
r2004
Reference power
p2005
Reference angle
p2006
Reference tempera
ture
p2007
Reference acceleration

Table of Contents