Basic functions
7.2 Reference parameters/scaling
Drive functions
318 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Scaling for the S_INF drive object
Table 7- 4 Scaling for the S_INF drive object
Size
Scaling parameter
Default when commissioning for the first time
Reference frequency
100% = p2000
p2000 = 50 Hz
Reference voltage 100% = p2001 p2001 = p0210
Reference current
100% = p2002
p2002 = r0206/p0210/√3
Reference power
100% = r2004
r2004 = r0206
Reference modulation
depth
100% = Maximum output
voltage without overload
-
Reference temperature
100 % = p2006
100°C
Reference electrical
angle
100 % = p2005 90°
Scaling for the B_INF drive object
Table 7- 5 Scaling for the B_INF drive object
Size
Scaling parameter
Default when commissioning for the first time
Reference frequency
100% = p2000
p2000 = 50 Hz
Reference voltage
100% = p2001
p2001 = p0210
Reference current
100% = p2002
p2002 = r0206/p0210/√3
Reference power
100% = r2004
r2004 = r0206
Reference temperature
100 % = p2006
100°C
Reference electrical
angle
100 % = p2005 90°