Basic functions
7.13 Motor Module as a Braking Module
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
353
U
DC link
chopper
threshold
Continu-
ous brak-
ing power
Resistance
at the continuous
braking power
Resistance
at the peak brak-
ing power
G
660 330 290 1070 380.0 570.1 1.506 1.004
H 500 410 400 841 412.0 618.0 0.858 0.572
H
H
J
J
600 810 805 967 953.4 1430.1 0.490 0.327
J
690 910 905 1158 1283.5 1925.3 0.522 0.348
J
J