EasyManua.ls Logo

Siemens SINAMICS S120 - Page 466

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function modules
Drive functions
466 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
You can also activate function modules in STARTER under "Configuration" > "Function
modules / technology packages". Function modules that are grayed-out in STARTER cannot
be activated via STARTER.
Commissioning via parameter (only with BOP20)
Function modules can be activated/deactivated using parameter p0108 of the Control Unit
(CU).
Overview of important parameters (see SINAMICS S120/S150 List Manual)
p0108[0..n]
Drive object function module
p0124[0...n]
Main component identification via LED

Table of Contents

Other manuals for Siemens SINAMICS S120

Related product manuals