Function modules
8.2 Extended monitoring functions
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
473
Function diagrams (see SINAMICS S120/S150 List Manual)
8010
Signals and monitoring functions
- Speed messages 1
8011
Signal
s and monitoring functions - Speed messages 2
8013
Signals and monitoring functions
- Load monitoring (r0108.17 = 1)
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Load monitoring
p2181[0...n]
Load monitoring, response
p2182[0...n]
Load monitoring, speed threshold 1
p2183[0...n]
Load monitoring, speed threshold 2
p2184[0...n]
Load monitoring, speed threshold 3
p2185[0...n]
Load monitoring, torque threshold 1, upper
...
p2190[0...n]
Load monitoring torque threshold 3, lower
p2192[0...n]
Load monitoring, delay time
Speed setpoint monitoring
p2150[0...n]
Hysteresis speed 3
p2151[0...n]
CI: Speed setpoint for messages
p2161[0...n]
Speed threshold 3
r2198.4
CO/BO: Status word, monitoring 2;
|n_set| ≤ p2161
r2198.5
CO/BO:
Status word, monitoring 2;
n_set < 0