EasyManua.ls Logo

Siemens SINAMICS S120 - Page 63

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Extended setpoint channel
3.1 Fundamentals
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
63
Setpoint sources
The closed-loop control setpoint can be interconnected from various sources using BICO
technology, e.g. at p1070 CI: Main setpoint (see function diagram 3030)).
There are various options for setpoint input:
Fixed speed setpoints
Motorized potentiometer
Jog
Fieldbus
Setpoint via PROFIBUS, for example
Analog inputs of the following exemplary components:
e.g. Terminal Board 30 (TB30)
e.g. Terminal Module 31 (TM31)
e.g. Terminal Module 41 (TM41)

Table of Contents

Other manuals for Siemens SINAMICS S120