EasyManua.ls Logo

Siemens SINAMICS S120 - Page 670

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety Integrated Basic Functions
10.2 General information
Drive functions
670 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Below is a list of standards and guidelines for safety technology.
EC Machinery Directive 2006/42/EC
This guideline defines basic protection measures for safety technology.
EN ISO 12100
Safety of machinery, basic terminology, general principles for design
EN 60204-1:2006
Safety of machinery - Electrical equipment of machines - Part 1: Electrical equipment of
machinery - General requirements
IEC 61508
Functional reliability of electrical and electronic systems
This standard defines "safety integrity levels" (SIL), which not only describe a certain
degree of integrity with regard to safety-oriented software but also defined, quantitative
error probability ranges with regard to the hardware.
IEC 61800-5-2
Adjustable-speed electrical power drive systems
Part 5-2: Safety requirements - Functional
Note
Certifications
In conjunction with certified components, the safety functions of the SINAMICS S120 drive
system fulfill the following requirements:
Safety integrity level 2 (SIL 2) according to IEC 61508.
Category 3 according to DIN EN ISO 13849-1
Performance level (PL) d according to DIN EN ISO 13849-1
In addition, the SINAMICS S120 safety functions are normally certified by independent
institutions. A list of currently certified components is available on request f
rom your local
Siemens office.
Note
Low-voltage directive
When operated in dry areas, SINAMICS devices with three
-phase motors conform to Low-
Voltage Directive 2006/95/EC.

Table of Contents