Communication
11.1 Communication according to PROFIdrive
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
747
Overview of closed-loop control
Position actual value sensing in the device is alternatively realized using an:
Indirect measuring system (motor encoder)
Additional direct measuring system
The encoder interface must be configured in the process data.
The control loop is closed via PROFIBUS.
The position controller is located in the controller.
The current and speed control and actual value sensing (encoder interface) are located in
the device.
The position controller cycle is transferred via the fieldbus to the devices.
The slaves synchronize their speed and/or current controller cycle with the position
controller cycle of the controller.
The speed setpoint is specified by the controller.
Figure 11-6 Overview of "Motion Control with PROFIBUS" (example: controller and 3 devices)