EasyManua.ls Logo

Siemens SINAMICS S120 - Page 772

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication
11.1 Communication according to PROFIdrive
Drive functions
772 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Channel-related diagnostics
Channel-related diagnostics encompasses the following data:
Bit
7
6
5
4
3
2
1
0
Octet
Name
x Header-
Byte
1
1)
0
1)
0 ... 63 (module number) including this byte
x + 1
1
2)
1
2)
0 (no component assignment)
x + 2 0
3)
0
3)
Message classes:
2 undervoltage
3 overvoltage
9 error
16 Hardware/software error
17 Line supply/filter faulted
18 DC-link overvoltage
19 Power electronics faulted
20 Electronic component overtemp.
21 Ground/phase fault detected
22 Motor overload
23 Commun. with controller faulted
24 Safety monit. Detected an error
25 Act. Position/speed value error
26 Internal communication faulted
27 Infeed faulted
28 Braking controller faulted
29 External signal state error
30 Application/function faulted
31 Parameterization/commiss. error
1)
≙ Channel-related diagnostics
2)
≙ Input/output
3)
≙ "Channel type "non specific"
System response
Only one signal is generated if channel-related diagnostics identifies several faults belonging
to the same message class at the same drive object.

Table of Contents

Other manuals for Siemens SINAMICS S120

Related product manuals