Basic information about the drive system 
  13.6 Inputs/outputs 
Drive functions 
Function Manual, 11/2017, 6SL3097-4AB00-0BP5 
967 
Function diagrams (see SINAMICS S120/S150 List Manual)  
 
  9102 
-  
isolated digital inputs (DI 0 ... DI 3) 
  9556 
Terminal Module 31 (TM31) 
-  
Digital relay outputs, electrically isolated (DO 0 ... DO 1) 
  2038 
-2 input/output terminals -  
Bidirectional digital inputs/outputs 
Signal processing using the bidirectional inputs/outputs is shown in the function diagrams 
listed below. 
●  Can be parameterized as digital input or output. 
●  When set as digital input: 
–  Six "high-speed inputs" on Control Unit 
If these inputs are used, for example, for the "flying measurement" function, they act 
as "high-speed inputs" with virtually no time delay when the actual value is saved. 
–  The properties of the "pure" digital outputs apply. 
●  When set as digital output: 
–  The properties of the "pure" digital outputs apply. 
●  Sharing of bidirectional input/output resources by the CU and higher-level controller (see 
Section "Use of bidirectional inputs/outputs on the CU (Page 969)")