EasyManua.ls Logo

Siemens SINAMICS S120 - Page 967

Siemens SINAMICS S120
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic information about the drive system
13.6 Inputs/outputs
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
967
Function diagrams (see SINAMICS S120/S150 List Manual)
TB30
9102
Terminal Board 30 (TB30)
-
isolated digital inputs (DI 0 ... DI 3)
TM31
9556
Terminal Module 31 (TM31)
-
Digital relay outputs, electrically isolated (DO 0 ... DO 1)
Control Unit 310-2
2038
CU310
-2 input/output terminals -
digital output (DO 16)
Bidirectional digital inputs/outputs
Signal processing using the bidirectional inputs/outputs is shown in the function diagrams
listed below.
Properties
Can be parameterized as digital input or output.
When set as digital input:
Six "high-speed inputs" on Control Unit
If these inputs are used, for example, for the "flying measurement" function, they act
as "high-speed inputs" with virtually no time delay when the actual value is saved.
The properties of the "pure" digital outputs apply.
When set as digital output:
The properties of the "pure" digital outputs apply.
Sharing of bidirectional input/output resources by the CU and higher-level controller (see
Section "Use of bidirectional inputs/outputs on the CU (Page 969)")