Basic information about the drive system
13.6 Inputs/outputs
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
971
The value of the analog input can be read out from r0755.
Function diagrams (see SINAMICS S120/S150 List Manual)
9104
Terminal Board 30 (TB30)
- Analog inputs (AI 0 ... AI 1)
9566
Terminal Module 31 (TM31)
- Analog input 0 (AI 0)
9568
Terminal Module 31 (TM31)
- Analog input 1 (AI 1)
9663
Terminal Module 41 (TM41)
- Analog input 0 (AI 0)
CU310-2:
2040
CU310
-2 input/output terminals - Analog input (AI 0)
Overview of important parameters (see SINAMICS S120/S150 List Manual)
r0752[0]
CO: CU analog input current input voltage/current
p0753[0]
CU analog input smoothing time constant
p0761[0]
CU analog input wire
-break monitoring response threshold
p0762[0]
CU analog input wire
-break monitoring delay time
p0763[0]
CU analog input offset
p0766[0]
CU analog input activate absolute
-value generation
p0769[0]
BI: CU analog input enable signal source
CU310-2:
r0755[0]
CO: CU analog input actual value in per
cent
p0756 [0]
CU analog input type
p0757[0]
CU analog input characteristic value x1
p0758[0]
CU analog input characteristic value y1
p0759[0]
CU analog input characteristic value x2
p0760[0]
CU analog input characteristic value y2