08/2005 Starting Up HMI Embedded (IM2)
4 Functions/Parameterization
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
IM2/4-45
1. Example: Operator panel front as main operator panel
; NETNAMES.INI Version 04.03.11 30.01.05
[own]
owner = MMC_1
; Description of possible connections
[conn MMC_1]
conn_1= NCU_1
; Description of significant net parameters
[param network]
bus= mpi
[param MMC_1]
mmc_address = 1
;only the first letter N or H will be
evaluated
name=VNC ;NCU -> connection using IP to 710s, ip=must
be specified
;HT8 -> connection using SPC2 to PCU with Linux,
ip will be ignored
;VNC -> or no name, connection to 710s with
internal HMI, ip will be ignored
[param NCU_1]
nck_address= 3 ,ip=127.0.0.1
plc_address= 2 ,ip=127.0.0.1
name = NCU710
; Description of a standard channel configuration
[chan MMC_1]
ShowChanMenu = TRUE
DEFAULT_logChanSet = ChannelArea1
DEFAULT_logChan = Channel11
logChanSetList = ChannelArea1
[ChannelArea1]
logChanList = Channel11,Channel12,Channel13
[Channel11]
logNCName = NCU_1
ChanNum = 1
[Channel12]
logNCName = NCU_1
ChanNum = 2
[Channel13]
logNCName = NCU_1
ChanNum = 3