Commissioning HMI Advanced (IM4) 08/2005
2 Setting Functions and Parameters
© Siemens AG, 2005. All rights reserved
IM4/2-28 SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
Spindle number: Numbers of the "logical" spindles to be included
(programmed in the DIN code with S1 to Sn; if more than
one applicable entry, the higher number is displayed)
2 channel status
The channel status and spindle status are output as an icon at the display position
(spindle status can be output deliberately, for example). The channel status icons
can be superimposed with the "Feed not enabled" icon.
The following hierarchy applies (from highest to lowest priority):
1. Channel STOP (Highest priority)
2. Feed is not enabled
3. Channel active
4. Channel RESET (Lowest priority)
Syntax:
ChanStatFeedStop = <Channel number>
Channel number: Number of channel
3 channel status
The channel status is output as an icon at the display position. Feed stop is also
output in the feed window in the Machine operating area, for example.
Syntax:
ChanStat = <Channel number>
Channel number: Number of channel
4 spindle status
The spindle status is output as an icon at the display position.
Syntax:
SpindStat = <Spindle number> , Chan <Channel number>
Spindle number: Number of (logical) spindle
Channel number: Number of channel optional
If the channel number is not specified, then the spindle status for the current
channel is displayed. If the channel is changed, the display is updated accordingly.
Configuration with HEADER.INI
The assignment of the cross-channel status display is defined in the HEADER.INI
file. It can optionally be configured with SINUMERIK and/or user icons.