Protection zones
3.3 Checking for protection zone violation, working area limitation and software limits (CALCPOSI)
Job planning
Programming Manual, 07/2010, 6FC5398-2BP40-0BA0
227
_BASE_SYS
FALSE or parameters not specified:
When evaluating the position and length data, the G code of
group 13 (G70, G71, G700, G710; inch/metric) is evaluated. If
G70 is active and the basic system is metric (or G71 is active
and inch), the WCS system variables $AA_IW[X] and
$AA_MW[X]) are provided in the basic system and must, if
necessary, be reconverted using the CALCPOSI function.
TRUE:
When evaluating the position and length data, the basic
system of the control is always used independent of the value
of the active G of group 13.
_TESTLIM
Limits to be checked (binary-coded):
1: Monitor software limits
2: Monitor working area limits
3: Monitor activated protection zones
4: Monitor pre-activated protection zones
Combinations by adding the values. Default: 15; check all.

Table of Contents

Other manuals for Siemens SINUMERIK 828D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D and is the answer not in the manual?

Siemens SINUMERIK 828D Specifications

General IconGeneral
Control TypeCNC
Operating SystemWindows Embedded
ProcessorIntel Atom
Display10.4" color TFT display
InterfacesEthernet, USB
ProgrammingShopMill, ShopTurn
Operation Panel Size10.4"
Protection ClassIP65
PLC Memory2 MB
Spindle Capacity4 spindles
Hard DriveCompactFlash

Related product manuals