Additional information on further system interfaces (Rear Side, Port B) Zusatz
Profibus DP Slave, RS485 + L 0 A
Profibus DP Slave, 820 nm, optical Double Ring, ST-Connector
1)
+ L 0 B
1)
Modbus RS485) + L 0 D
Modbus, 820 nm, optical, ST–Connector
2)
+ L 0 E
2)
DNP3.0, RS485 + L 0 G
DNP3.0, 820 nm, optical, ST-Connector
2)
+ L 0 H
2)
IEC 60870-5-103 Protocol, redundant RS485 connector
2)
+ L 0 P
2)
IEC 61850, Ethernet electrical, double, RJ45–Connector (EN 100) + L 0 R
IEC 61850, Ethernet optical, double, duplex LC connector (EN 100)
2)
+ L 0 S
2)
DNP3 TCP via IP, 100 Mbit Ethernet electrical, double, RJ45 connector (EN 100) + L 2 R
DNP3 TCP via IP, 100 Mbit Ethernet optical, double, duplex LC connector (EN 100)
2)
+ L 2 S
2)
PROFINET via IP, 100 Mbit Ethernet electrical, double, RJ45 connector (EN 100) + L 3 R
PROFINET via IP, 100 Mbit Ethernet optical, double, duplex LC connector (EN 100)
2)
+ L 3 S
2)
1)
Cannot be delivered in connection with the 9th digit = "B". If the optical interface is required, the order must
be as follows: 11. digit = 4 (RS485) and additionally the associated converter.
Cannot be delivered in connection with the 9th digit = "B".
Converter Order No. Use
SIEMENS OLM
1)
6GK1502–2CB10 for single ring
SIEMENS OLM
1)
6GK1502–3CB10 for double ring
1)
The converter requires an operating voltage of 24 V DC. If the available operating voltage is > 24 V DC the
additional power supply 7XV5810–0BA00 is required.
DIGSI/Modem Interface (Rear Side, Port C)
Pos. 12
No DIGSI Interface at the back 0
DIGSI/Modem, electrical RS232 1
DIGSI/Modem/RTD-Box
1)
, electrical RS485
2
DIGSI/Modem/RTD-Box
1)
, optical 820 nm, ST-Connector
2)
3
1)
RTD-box 7XV5662–*AD10
2)
If the RTD-Box is to be run at an optical interface, an additional RS485–FO–Converter 7XV5650–0*A00 is
required.
Measuring/Fault Recording
Pos. 13
With fault recording 1
With fault recording, average values, min/max values 3
Functions Pos. 14
and 15
Designation ANSI-Nr. Description F A
Basic function (contained
in all versions)
Control
50/51 Time overcurrent protection phase 50 -1, 50-2, 50-3, 51, reverse
interlocking
50N/51N Ground fault protection ground 50N-1, 50N-2, 50N-3, 51N
50N/51N
Insensitive ground fault protection via SGFD function
1)
50/50N Flexible protection functions (parameters from current): additive
overcurrent time protection elements
49 Overload protection (with 2 time constants)
46 Unbalanced load protection
37 Undercurrent monitoring
Ordering Information and Accessories
A.1 Ordering Information 7SJ61 V4.9
SIPROTEC 4, 7SJ61, Manual 347
C53000-G1140-C210-6, Edition 05.2016