Siemens XC1003-A - Safety regulations; Danger levels; Safety-relevant operating instructions

Siemens XC1003-A
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
About this document
6
Building Technologies
A6V10099837_a_en
Fire Safety & Security Products 12.2007
Brief description of chapter contents
Chapter Content Overview
1. About this document General information on documentation and notes
on the target group for which the document was
created.
2. Safety regulations Describes the hazard levels and safety provisions
that are important for planning, installation,
commissioning and maintenance of the
extinguishing control unit.
3. System overview Provides an overview of the function, use and
connection options for peripheral devices.
4. Standard application Illustrates and describes the two possible
topologies (centralized and modular) used in the
standard application.
5. Structure and function Describes the structure of the control unit,
electrical connections and the function of the
indicator elements, the operating elements and
the accessories; it also includes technical data.
6. Planning Describes the principle structural features of an
extinguishing control unit using descriptions of the
connection of peripheral devices.
7. Installation Provides procedural instructions for mounting the
control unit and any accessories.
8. Commissioning Provides procedural instructions for connecting
the peripheral devices and commissioning of the
extinguishing system.
9. Service Describes the recommended maintenance work.
10. Detailed procedures Supplements the instructions on commissioning
and maintenance using detailed, unit-specific
procedures.
11. User function configuration Describes the programming functions for a
customer-specific configuration of the
extinguishing unit.
12. Log sheet of programmed user functions Here you will find the worksheets for completion.
13. Ordering information Information on ordering components, accessories
and replacement parts.
Reference documents
Number/Version Name
A6V10099835_a_en Operating instructions
Standard symbols
Result, Note
' ' Direct quotation
(...) Parentheses contain supplementary text, suggestions, etc.
Technical terms
Term Explanation
Fire alarm The first alarm stage. The fire alarm time is the time between
triggering of the first and the second detector.
Activated condition Second alarm stage. The activated time is the time leading up to
triggering of the extinguishing releasing element.
Pre-discharge-warning time
Time period between the start of the warning indication and the
discharge to warn personnel of impending gas release
Flooding time The period of time during which the extinguishing gas is discharged.
Actuator An electromagnetic or pyrotechnical releasing element for triggering
the valves.
LED An optical indicator element (light-emitting diode).