Log sheet of programmed user functions
90
Building Technologies
A6V10099837_a_en
Fire Safety & Security Products 12.2007
12 Log sheet of programmed user functions
Installation: ..................................................................................................................
Step
Function
Option,
default
Option,
individual
Change the activated time of the control line 4 7 1
Change the function of control line 5 14
Change the flood time of control line 4 1 2
Change the flood time of control line 5 6
Change the function of contact 1 1
Change the function of contact 3 5
Change the function of contact 2 8, 10
Change the function of LED 9 (remote transmission) and LED 6 (Fire alarm) 12, 15
3
Change the function of control line 2 17
Change the function of monitored input 1 1
Suppress the fault indication if state "Released" is not reported 4
4
Change the function of monitored input 2 6
Change the active mode of control line 1 1, 5, 9
Change the active period of control line 1 11
5
Change the active mode and active period of control line 3 15, 18, 20
Enable "Alarm Verification" function of detector zones 1 and 2 1
Enable "Alarm Verification" function of detector zone 3 3
6
Enable "Alarm Verification" function of detector zones 4 5
Deleted 1 1
Deleted 7, 9 7, 9
7
Deleted 11 11
Change the function of monitored input 3 1
Suppress "Reset" upon "stopped activated time by monitored Input 3" 8
8
Change the fault processing of the monitored input 3 10
Change the reaction after "Reset" of the detector zones 1 and 2 1
Change the reaction after "Reset" of the detector zone 3 3
Change the reaction after "Reset" of the detector zone 4 6
Change the reaction after "Reset" of the monitored Input 1 8
Interlock the "Reset" function if executed via control input 1 10
9
Interlock the "Reset" function 11
Change the indication of the blocking states 1 10
Change active mode of indicator "Released" 3
Change the function of detector zones 1 and 2 1
Change the line fault processing of the detector zones 1 and 2 6
11
Change the function of detector zone 3 9
Change the basic code for Access Level 2 1 12
Change the access level for the function "Silence Buzzer" 4
Change the processing of "Fire alarm condition" 1
Change the function of the key "Silence buzzer" 3
Enable the function "Reminder Beep" 5
Enable the function "Fault to be Reset" 7
Enable the function "RT-Alarm + RT Fault suppressed on Access Level 2" 9
Enable the function "Reset via control input 1 suppressed upon state RT-Alarm" 11
Suppress the "battery fault" 13
13
Change the active mode of the buzzer in state "Emergency hold/abort" 15
14 Change the fault delay in the event of mains failure 3
Change the function of control input 2 1
Change the function of control input 3 8
15
Change the function of control input 4 15
Change the function of driver output 2 1, 9
Change the function of driver output 8 10, 18
16
Change the function of driver output 1 20