Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
394
1…24,100…179
<longitude>
Current longitude in degrees.
<latitude>
Current latitude in degrees.
<detail_addr>
Current detail address
. It based the UCS2 coding. Each 4 characters in the URC is for one
UCS2 character.
<acc>
Positioning accuracy.
<lon_type>
The type of longitude and latitude
0 WGS84,the default type
1 GCJ02.
<times>
access service times.
<data>
service date(UTC, the format is YYYY/MM/DD,HH:MM:SS).
<time>
service time(UTC, the format is YYYY/MM/DD,HH:MM:SS).
<ret_code>
The result code.
0 Success
1 Parameter error returned by server.
2 Service out of time returned by server.
3 Location failed returned by server.
4 Query timeout returned by server.
5 Certification failed returned by server.
6 Server LBS error success.
7 Server LBS error failed.
80 Report LBS to server success
81 Report LBS to server parameter error
82 Report LBS to server failed
110 Other Error
8 LBS is busy.
9 Open network error.
10 Close network error.
11 Operation timeout.
12 DNS error.
13 Create socket error.
14 Connect socket error.
15 Close socket error.
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7600 Series and is the answer not in the manual?

SimCom SIM7600 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7600 Series
CategoryControl Unit
LanguageEnglish

Related product manuals