Electrical System
9-41
6036, 6042, 8042, 10042, 10054 31211015
9.16.4 Personalities
Menu/
Sub-
menu
Items
Function Description
Default Values (Range)
Access
Level
6036, 6042, 8042, 10042, 10052, 10054
Fork Tilt
Accel Up: x.xS
Fork tilt screen allows
the operator to view
the parameters (min/
max values) related to
fork tilt
0.1
(0.0 – 5.0S)
Access
Level 2, 3
Decel Up: x.xS
0.3
(0.0 – 5.0S)
Accel Down: x.xS
0.1
(0.0 – 5.0S)
Decel Down: x.xS
0.3
(0.0 – 5.0S)
Min Up: xxxxmA
600mA
(100 – 1000mA)
Max Up: xxxxmA
1300mA
(500 – 1700mA)
Min Down: xxxxmA
600mA
(100 – 1000mA)
Max Down: xxxxmA
1300mA
(500 – 1700mA)