EasyManuals Logo

SNR S2940-8G-v2 User Manual

SNR S2940-8G-v2
420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #416 background imageLoading...
Page #416 background image
SNR S2940-8G-v2 Switch Configuration Guide
Monitor and Debug
• Restart the switch, mission abnormal, hot plug on the CHASSIS switch chips are classified
critical
• Up/down interface, topology change, aggregate port state change of the interface are notifi-
cations warnings
• Outputted information from the CLI command is classified informational
• Information from the debugging of CLI command is classified debugging
Log information can be automatically sent to corresponding channels with regard to respective
severity levels. Amongst the debugging information can only be sent to the monitor. Those with the
Informational level can only be sent to current monitor terminal, such as the information from the
Telnet terminal configuration command can only be transmitted to the Telnet terminal. Warnings
information can be sent to all terminal with also saved in the SDRAM log buffer zone. And the
critical information can be save both in SDRAM and the NVRAM (if exists) besides sent to all
terminals. To check the log save in SDRAM and the NVRAM, we can use the show logging buffered
command. To clear the log save in NVRAM and SDRAM log buffer zone, we can use the clear
logging command.
66.7.2 System Log Configuration
System Log Configuration Task Sequence:
1. Display and clear log buffer zone
2. Configure the log host output channel
3. Enable/disable the log executed-commands
4. Display the log source
5. Display executed-commands state
1. Display and clear log buffer zone
Command Explanation
Admin Mode
show logging buffered [ level { critical | warn-
ings } | range <begin-index> <end-index>]
Show detailed log information in the log buffer
channel.
clear logging { sdram | nvram } Clear log buffer zone information.
2. Configure the log host output channel
Command Explanation
Global Mode
logging { <ipv4-addr> | <ipv6-addr> } [ facil-
ity <local-number> ] [level <severity>]
no logging { <ipv4-addr> | <ipv6-addr> } [
facility <local-number>]
Enable the output channel of the log host. The
'no' form of this command will disable the output
at the output channel of the log host.
416

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SNR S2940-8G-v2 and is the answer not in the manual?

SNR S2940-8G-v2 Specifications

General IconGeneral
BrandSNR
ModelS2940-8G-v2
CategorySwitch
LanguageEnglish