SE7600A-US
1
Unit
Lower Power Output Higher Power Output
AC Circuit Breaker Yes
THD < 5 %
Power factor with rated power 0.2 leading to 0.2 lagging
Automatic switchover time < 2 sec
Typical Nighttime Power Consumption < 5 W
INPUT - DC (PV and BATTERY)
Transformer-less, Ungrounded Yes
Max Input Voltage 500 Vdc
Nom DC Input Voltage 400 Vdc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 600kΩ Sensitivity
Maximum Inverter Efficiency 98 %
CEC Weighted Efficiency 97.5 %
INPUT - DC (PV)
Maximum DC Power (STC) 10250 W
Max Input Current
2
23 Adc
2-pole Disconnection Yes
INPUT - DC (BATTERY) - FOR HIGH POWER
Supported Battery Types LG Chem RESU10H
Number of Batteries per Inverter 1
3
Continuous Power 3300 5000 W
Peak Power 5000 7000 W
Max Input Current 8.5 17.5
DC Fuses on Plus and Minus 12A (field replaceable) 25A (field replaceable)
2-pole Disconnection Yes
ADDITIONAL FEATURES
Supported Communication Interfaces
RS485 for battery, RS485, Ethernet, ZigBee (optional).
Cellular (optional)
Battery Power Supply Yes, 12V / 53W
1
These specifications apply to inverters with part numbers SE7600A-USS2XXXXX and connection unit model number
BCU-1PH-USS.
2
A higher current source may be used; the inverter will limit its input current to the values stated.
3
For two LG Chem batteries connection, contact SolarEdge.
StorEdge Single Phase Inverter with Connection Unit for High Power - Technical
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3