EasyManua.ls Logo

Solo MINI - 0 X8 A: Speed Controller Ki Gain; 0 X8 B: Output PWM Frequency ( Switching Frequency); 0 X8 C: Current Limit

Solo MINI
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SOLO Communication Manual - UART and USB
www.solomotorcontrollers.com
September 2021 - Revision V_1.0.1 Copyright © 2021, All right Reversed. SOLO motor controllers.
46
0x8A : Speed Controller Ki Gain
Code: 0x89
Speed Controller Kp Gain
Data Type
Data Range
Units
Memory Storage
Default Value
Sfxt(32-17)
[0.0 - 16000.0]
N/A
M
0
Description:
This command reads the value of the Speed controller Ki gain, set for Digital mode operations.
0x8B : Output PWM Frequency ( Switching Frequency)
Code: 0x--
Set Device Address
Data Type
Data Range
Units
Memory Storage
Default Value
Uint32
[8000-80000]
Hz
M
20000/80000
Description:
This command reads the output switching frequency of SOLO in Hertz.
0x8C : Current Limit
Code: 0x8C
Current Limit
Data Type
Data Range
Units
Memory Storage
Default Value
Sfxt(32-17)
[0.2 - 32.0]
Amps
M
0
Description:
This command reads the value of the current limit set for SOLO in closed-loop digital