EasyManua.ls Logo

Sony CCD-TR618 - Camera System Adjustments; Lens Type Input; HALL Adjustment

Sony CCD-TR618
234 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-14
1-3. CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are
satisfied.
2. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject Not required
Measurement Point Display data of page 1 (Note1)
Measuring Instrument Adjustment remote commander
Adjustment Page F
Adjustment Address 38, 39, 3A
Specified Value 1 86 to 8A
Specified Value 2 15 to 19
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
IRIS display data
Adjusting method:
Order Page
Address
Data Procedure
1 0 01 01 Set the data.
2 6 94 88 Set the data.
3 6 95 17 Set the data.
4 6 01 6D Set the data, and press PAUSE
button.
5 6 02 Check that the data changes to
“01”. (Note2)
6 6 01 00 Set the data, and press PAUSE
button.
Note2: The adjustment data will be automatically input to page: F,
address: 38, 39, 3A.
Checking method:
Order Page
Address
Data Procedure
1 0 03 03 Set the data.
2 6 01 01 Set the data, and press PAUSE
button.
3 1 Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4 6 01 03 Set the data, and press PAUSE
button.
5 1 Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Processing after Completing Adjustments:
Order Page
Address
Data Procedure
1 6 94 00 Set the data.
2 6 95 00 Set the data.
3 6 01 00 Set the data, and press PAUSE
button.
4 0 03 00 Set the data.
5 0 01 00 Set the data.
Note: NTSC model: CCD-TR618/TR818/TRV49/TRV58/TRV68/TRV78/TRV88/TRV98
PAL model: CCD-TR618E/TR718E/TR728E/TRV49E/TRV58E/TRV59E/TRV78E/TRV98E
1. Lens Type Input
Distinguish the type of the lens being used for the camcorder, and
input data corresponding to the type.
Subject Not required
Measurement Point Display data of page 1 (Note)
Measuring Instrument Adjustment remote commander
Adjustment Page E F
Adjustment Address 5C, 5D, 5E, 5F 2C
Note: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Adjusting method:
Order Page
Address
Data Procedure
1 0 01 01 Set the data.
2 6 01 65 Set the data, and press PAUSE
button.
3 0 03 19 Set the data.
4 1 Check that the data.
When the data is “0000”,
proceed to step 5.
(Glass lens type)
When the data is “0001”,
proceed to step 11.
(Plastic lens type)
5 E 5C 21 Set the data, and press PAUSE
button.
6 E 5D 84 Set the data, and press PAUSE
button.
7 E 5E FC Set the data, and press PAUSE
button.
8 E 5F F7 Set the data, and press PAUSE
button.
9 F 2C D6 Set the data, and press PAUSE
button.
10 Proceed to step 16.
11 E 5C 22 Set the data, and press PAUSE
button.
12 E 5D 51 Set the data, and press PAUSE
button.
13 E 5E FD Set the data, and press PAUSE
button.
14 E 5F C4 Set the data, and press PAUSE
button.
15 F 2C D7 Set the data, and press PAUSE
button.
16 6 01 00 Set the data, and press PAUSE
button.
17 0 03 00 Set the data.
18 0 01 00 Set the data.

Table of Contents

Related product manuals