81TS 700, TS 800
: Screw on nuts (arrows) and
tighten them down until the test
flange lies completely flush
against the carburetor.
376RA372 TG
: Turn the lower lever
anticlockwise until the rod (1) is
securely pressed against the
upper end of the oblong hole in
the lever (arrow).
1
376RA223 TG
The lever (1) must not be at the top
dead centre = TDC.
: Press the air flap shut with a
suitable blunt tool (arrow) and
hold it shut.
: Align the lower lever (1) in
1
OT
2
A
376RA373 TG
accordance with position (A) so
that the rod (2) is vertical.
Press the lever (1) onto the
ribbed part of the air flap shaft.
The air flap lever is now fixed in
position.
: Insert the screw (1) and tighten it
down.
1
376RA225 TG
Wind the leg spring (1) roughly
one turn anticlockwise to tension
it.
: Hook the leg spring (1) into the
elbow connector (arrow).
1
376RA224 TG
Check correct functioning.
: Throttle shutter (arrow) and air
flap (arrow) must be horizontal in
full throttle position.
When the throttle shutter opens, the
air flap opens with a delay equal to
376RA382 TG
roughly one-third of the throttle
shutter opening.
Reassemble parts in reverse
order.