SUNWARD SWDE200B - Air Filter Maintenance; Cooling System Maintenance

SUNWARD SWDE200B
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SWDE200B Operation & Maintenance Manual
78
3. Safety Valve
Check clogging or damage
4.Oil Filter
Change Filter Element
after initial 50 running
hours
5. Secondary Oil
Return Pipe
Clean oil return check
valve after initial 50
running hours
6. Air Filter
Maintain the major filter
element
7. Oil Filter
Change filter element
8. Hose
Check hoses , and change
that if necessary
9. Lubricating Oil
Change lubricating oil
10. Secondary oil
return pipe
Clean oil return check
valve and the filter
11. Oil-gas
separator element
Change when discharging
gas with much oil
12. Air Filter
Change main filter element
and safety filter element
13. Rubber Hose
Change lubrication
pipeline and controlling
rubber pipes
Warning: Never start the air compressor unit in unsafe conditions. Compressed air in the
air compressor system should be discharged completely prior to maintenance; failure to
comply may result in accidents and personal injury!