SWDE200B Operation & Maintenance Manual
77
7.4.8 Air Conditioner
Item
Method
Interval Time (Hour)
8
50
250
1000
2000
Cooling System
Refrigeration
State
Observe the flowage state from
liquid inspecting mirror
Pipe line
Check hoses if there is breakage,
damage
Check all connectors if there is
leakage
Check all clamps if there is slack
or damage
Compressor
Cooling oil
Change SP-20 cooling oil
Belt
Check belt tension if there is
wear and tear
Compressor
bracket
Check if it is workable and fixed
firmly
Condenser
Condenser
core
Check if it is clean or damaged
Front body of
condenser
Check if there is sundries
Condenser
bracket
Check if there is slack or
damage
Evaporator
Evaporator
bracket
Check if it is damaged or fixed
firmly
Recycle air
gate
Check if it is ventilated well
Fan
Check if it is in good condition
and workable
7.4.9 Air Compressor System
Maintenance Parts
Procedures
Interval (hours)
10
50
300
500
1200
2000
1Air Filter
Clean dust outlet, and
maintain the element if
there’s an alarm
2. Oil-Gas
Separator
Discharge accumulated
condensate water