7.0 SG-DRL5/DRL5E/DRL5-2L PSTN Line Cards
- 120 -
When Option 194/294 is set to 01, the leading digit of a 4-digit account code is stripped if it is an F.
Standard 4/2 format Output:
1RRLLLssssssAAAAsXssYZ
Example 1:
Option 194/294 set to 01: Panel account code is F245
104091ssssssF245sXssYZ
IF Option 194/294 is set to 01 the 'F' is replaced by a space.
104091sssssss245sXssYZ
This setting also enables the receiver to decode special pulse extended-extended formats.
104091sssssss245sXssYZ
If Option 194/294 is set to 02 then the leading digit of any account code greater than four digits is stripped if it is a zero.
This option works with the following formats:
Standard Pulse and DTMF(3/x, 4/x & Extended)
FBI
Ademco Super Fast (4/8/1, 4/8)
Contact ID
ITI
SIA
Modem II
SKFSK
Example 1:
Option 194/294 set to 02
Panel account code is 0345
104091ssssss0345sXssYZ
New Output:
104091sssssss345sXssYZ
Details on "special pulse extended-extended" formats:
Option 194/294 = 01, This option applies to pulse formats. If any of the reporting code digits are an A, they are reported on the computer and printer as
an A instead of a 0.
4 digits:
If two rounds match, decode the 4 digit pulse extended format in the form of:
26AC x2 =>KO (last digit must be C)
CCC2 x2 =>KO (1st 3 digits must be C)
26AF x2 =>KO (last digit must be F)
FFF2 x2 =>KO (1st 3 digits must be C)
-------
26AC2F2
Otherwise decode as 3-1 extended or normal 3-1, and if the first digit is F strip it off.
5 digits:
If the checksum is good, decode the 5 digit pulse extended format in the form of:
26ACF =>KO (2nd last digit must be C)
CCC27 =>KO (1st 3 digits must be C)
26AFC =>KO (2nd last digit must be F)
FFF2D =>KO (1st 3 digits must be C)
-------
26AC2F2
Otherwise decode as 3-1 extended or normal 3-1, and if the first digit is F strip it off.
Do normal decoding based on options (4-1, 4-1 extended, 3-1checksum, 3-2) and if the first digit is F strip it off.
6 digits:
If two rounds match, decode the 6 digit pulse extended format in the form of:
F1231F
F1231F =>KO (last two digits must be 1F to 8F)
F12301
F12301 =>KO (last two digits must be 01 to 06)
F123B2
F123B2 =>KO (last two digits must be B0 to BF)
-------
1231F01B2
Otherwise decode as 4-2.