7.0 SG-DRL5/DRL5E/DRL5-2L PSTN Line Cards
- 123 -
SG-DRL5 Option 19C/29C: Acron RS-232
Default 01
When this option is programmed as '00', the receiver will convert the Acron Super Fast format signal into the standard 3/2 or 4/2 format:
1RRLLLssssssAAAAsXssYY[DC4]
Where 1 = protocol number
RR = receiver number LLL = line number
ssssss = spaces AAAA = account code
X = Event Code
YY = Zone Number
And to the printer with the library text as:
RR-LLL-AAAA-YY-Text
If the Acron options is programmed as '01' the Acron Super Fast format will be sent to the automation as indicated below:
9RRLLLssssAAAACCCCCCCCC[DC4]
Where 9 = protocol number
RR = receiver number
LLL = line number
ssss = spaces
AAAA = account code
CCCC = channel 1-4
CCCC = channel 5-8
[DC4] = terminator
And to the printer with no library text as:
RR-LLL-AAAA-CCCCCCCC-
SG-DRL5 Option 19D/29D: MODEM II RS-232 - Default 01
In order for the line card to receive the Modem II formats, two of the handshakes should be programmed 0B or 0E. The Modem II RS-232 option con-
trols how the receiver will output alarms to the automation. This option is a bit-selectable option meaning more than one bit may be enabled.
Bit 0: OFF: Select protocol: 1RRLLLssssssAAAAXXYYYY[DC4]
ON: Select protocol: 6RRLLLssssssAAAAXXYYYY[DC4]
Bit 1: OFF: Do not convert to SIA protocol
ON: Convert Modem II to SIA protocol: RRRLLL[#AAAA|EYYZZZ][DC4]
Bit 2: OFF: Do not convert to SIA with Modem II ASCII text blocks.
ON: Convert to SIA protocol with Modem II ASCII text blocks as
SRRLLL[#AAAA|EYYZZZ][DC4] and
RRRLLL[#AAAA|A....][DC4].
Bit 3: OFF: Only decode the first 4 digits of Modem II account codes even if more than 4 received.
ON: Decode up to 10 digits of Modem II account codes.
The default is 0x01 meaning output with 6RRLLL protocol. Do not convert to SIA, do not process Modem II text blocks, and only decode the first 4
digits of Modem II account codes.
NOTE: The lowest bit will also affect the BFSK format decoding.
NOTE: Ensure that the automation software supports settings 02 and 06 if the SIA protocol is desired.
SG-DRL5 Option 19E/29E: Scantronics Select
Default (00)
When this option is programmed as '00', 14-digit DTMF will be decoded as Scantronics 4-8-1 with Checksum.
When this option is programmed as '01', 14-digit DTMF will be decoded as Scantronics 5-8-1.
SG-DRL5 Option 19F/29F: Ademco High Speed RS-232
Default 01
When this option is programmed as '00', the receiver will convert the High Speed format signal into 4/2 format automation:
1RRLLLssssssAAAAsXssYY[DC4]
printer: RR-LLL-AAAA-YY-Alarm
When this option is programmed as '01' the Ademco High Speed will not be decoded, and the received data is passed to the outputs.
8RRLLLAAAAsCCCCsCCCCsC[DC4]
Where 8 = protocol number
RR = receiver number