Chapter 5 Command Reference
Error Messages/Codes
106 Operating and Programming Manual
Error Messages/Codes
Table 5-7 lists and describes the error messages.
Table 5-7. Error Messages
Number
Error String
Cause
-100
Command error
This is the generic syntax error used if the 5071A cannot detect
more specific errors.
-101
Invalid character
Unrecognized character in specified parameter.
-102
Syntax error
Command missing space/comma between parameters.
-103
Invalid separator
Command parameter separated by space is a not comma.
-104
Data type error
Wrong data type specified in parameter.
-108
Parameter not allowed
Parameter specified in parameterless command.
-109
Missing parameter
Parameter missing in entered command.
-112
Program mnemonic too
long
Header contains more than 12 characters.
-113
Undefined header
Command header incorrectly specified.
-121
Invalid character in
number
Entered character for numeric data is incorrect.
-123
Exponent too large
Exponent larger than 32000.
-124
Too many digits
More than 256 digits specified.
-128
Numeric data not
allowed
Number specified for parameter not letter.
-131
Invalid suffix
Parameter suffix incorrectly specified.
-134
Suffix too long
The suffix contained more than 12 characters.
-138
Suffix not allowed
Parameter suffix specified when not allowed.
-141
Invalid character data
Parameter type specified not allowed.
-144
Character data tool long
Character data element has more than 12 characters.
-148
Character data not
allowed
Entered character data not recognized by instrument.
-150
String data error
Entered string data contained a non-specific error.
-151
Invalid string data
Entered string data syntax invalid.
-158
String data not allowed
String data encountered but not allowed.
-160
Block data error
Entered block data contained a non-specific error.

Table of Contents

Other manuals for Symmetricom 5071A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom 5071A and is the answer not in the manual?

Symmetricom 5071A Specifications

General IconGeneral
BrandSymmetricom
Model5071A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals