Insert the splash guard for the electronics with the actu-
ation motor. The activation hooks must fit correctly in the
drain valve's drawbar eyelets. Tighten the splash guard
clamping screws.
Finally, install the flush plate.
... Toilet module (dry-wall and brick-wall) without conduits
Connect the cable from the transformer to the mains con-
nection adapter (ensure correct polarity – see details in fig.
).
Guide the cable from the actuation motor and the power
supply through the opening on the bottom left of the
splash guard.
Then, insert the splash guard with the actuation motor. The
activation hooks must fit correctly in the drain valve's draw-
bar eyelets. Tighten the splash guard clamping screws.
Connect the cable from the switch on the safety support
arm to the electronics (terminal strip). Ensure correct polar-
ity.
-
Flush plates