BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 2.31
BS-00: Zero sensor extension cable
Bio Driver Board – Patch
Bio Driver
Board
CN4
Signal Color Open
CN27
1 Signal White 1
2 Ground Black 2
BS-0: Zero sensor cable
Zero sensor – Patch
Zero sensor Signal Color Open
CN27
Signal White 1
Output
Ground Black 2
BS-2/2R: Weight stack motor cable
Bio Driver Board – Patch cord
Bio Driver
Board
CN1
Signal Color Open
CN21
1 + motor Black 1
2 - motor Red 2
4 + 12 Vdc White 4
5 Pulses Green 5
6 Ground Orange 6
BS-9/2: Weight stack cable
Bio Driver Board – Patch cord
Open Bio Driver Board
CN3
Signal Color
CN23 CN24
1 Channel A Black 1 -
2 Channel B Red 2 -
3 +12 Vdc White 3 -
4 Ground Green 4 -
5 + solenoid Orange - 4
6 Solenoid ground Blue - 3