BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 2.32
BS-10: Solenoid extension cord
Patch – Patch
Patch
CN25
Signal Color Open
CN26
3 + solenoid Blue 3
4 Solenoid ground Red 4
BS-25/LP: LP seat motor cable
Bio Driver Board – Patch cord
Bio Driver
Board
CN6
Signal Color Open
2 Motor up Red 2
3 Motor down White 3
4 Alarm Green 4
5 Pulses Orange 5
6 Ground Blue 6
BS-27/2ALP: LP seat motor cable
LP Driver Board – Patch cord
LP Driver
Board
CN1
Signal Color Open
1 + motor Black 1
2 - motor Black 2
BS-28/2ALP: LP seat motor component cable
LP Driver Board – Patch cord
LP Driver
Board
CN4
Signal Color Open
1 +5Vdc photocell Black 1
2 Rear switch Red 2
3 Pulses White 3
4 Front switch Green 4
5 Ground photocell Orange 5
6 Ground microswitches Blue 6
The connection cables between cable BS-27/2ALP and the seat motor and between cable BS-
28/2ALP and the photocell and the 2 microswitches are not reported because easily described on the
wiring diagram.