SELECTION LINE: Service & Maintenance Manual - rev. 4.0
Page 7.3
Figure 7.3-1
Use a torque wrench to check that they are locked down with the prescribed torque of 13 Nm / 9.6
ft.lbs..
7.4. FIX THE HOOK ON THE BAR OF MULTIPOWER:
SOLUTION TO PREVENT THE HOOK FROM BECOMING
FREE
7.4.1. EQUIPMENTS WITH SN UP TO M95315100401
For Multipower equipment with SN up to M95315100401, if you need to replace hooks and /or the
hook becomes free, YOU MUST ORDER AND INSTALL the kit SR0007088AA.
WARNING: the code SR0007088AA applies only to SELECTION Multipower. For ELEMENT+
and SELECTION MED Multipower, you must order another kit. (For details refers to Parts Catalogue
and ELEMENT+ / SELECTION MED Technical Service Guides).
The kit contains:
- 2 hooks;
- 4 special sharp screws (nut + screw glued);