3-16
dn-02 (Digital output contact signalstatus)
Users can use
dn-02
to check current digital output contact signal status. The following is the
description of panel display:
When a digital output contact signal status is ON, the corresponding LED will light up. When a
digital output contact status is OFF, the corresponding LED will not light up. The following
comparison table shows LED No. and digital output contact code.
DO-1
~
DO-8
are multifunction
planning contact and can be set by
Hn613~Hn616 & Hn619~Hn622
. They can also be set as switch
in conduction or open under ON status. Please refer to “5-6-1 Digital input/output contact function
planning” to set their functions.
DO-5
~
DO-8
are digital output contact with determined functions.
LED No. Output Contact Code
1 DO-1
2 DO-2
3 DO-3
4 DO-4
5 DO-5
6 DO-6
7 DO-7
8 DO-8