4-13
tn832.0 Program Jog operation flag
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Take effect after setting
1320H
Setting description:
Setting Description
0 Disable stroke operation
1 Enable stroke operation
tn832.1 Program Jog execution direction selection
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 3 --
1320H
Setting description:
Setting Description
0 Forward=>Reverse
1 Reverse=>Forward
2 Forward=>Forward
3 Reverse=>Reverse
tn833 Program Jog stroke stop time
Initial Value Unit Setting Range Effective RS-485 Address
2500
0.4ms
5 ~ 25000 Take effect after setting
1321H
Setting description: Program Jog stroke stop time
tn834 Program Jog stroke acceleration/deceleration time
Initial Value Unit Setting Range Effective RS-485 Address
250
0.4ms
5 ~ 25000 Take effect after setting
1322H
Setting description: Program Jog stroke acceleration/deceleration time
tn835 Program Jog stroke moving speed
Initial Value Unit Setting Range Effective RS-485 Address
100
rpm
0 ~ 1.5 x rated rotation speed
Take effect after
setting
1323H
Setting description: Program Jog stroke movement maximum speed
tn836 Program Jog stroke moving distance
Initial Value Unit Setting Range Effective RS-485 Address
30
0.1rev
1 ~ 2000 Take effect after setting
1324H
Setting description: Program Jog stroke moving distance